D-120
ID:131750 View:477次 |
Date Listed: | 2016-10-22 18:06:59 | Country: | China»Zhejiang»yueqing |
Poster: | Xiaoyan yu | Company: | ZHEJIANG WEIHAO ELECTRONIC CO.,LTD |
Location: | No.231,WeiLiu Road | Website: | ZHEJIANG WEIHAO ELECTRONIC CO.,LTD |
Email: | wehodz@chnwh.com | Mobile: | 86-15325082200 |
Fax: | 86-577-61777072 | MSN: |
Features:High efficiency, high reliabilitySwitch input voltage range choice100% full load and machine testProtection characteristics: short circuit/overload/pressureAir coolingWorking frequency 47~63 Hz1 year warrantySize: 199 * 110 * 50 mm (L * W * H)?modelD-120AD-120BCH1CH2CH1CH2outputDc output voltage5V12V5V24VOutput voltage tolerance?2%?6%?2%?7%Rated output current12A5A6A4AOutput current range0-12A0-5A0-6A0-4AOutput power120W126WRipple and the noise60mVp-p120mVp-p60mVp-p150mVp-pDc voltage adjustable scopeCH1?-5%,+10%CH1?-5%,+10%Start, rise, keep time200ms,50ms,20ms Loaded withinputInput voltage range88?132 VAC / 176?264VAC 47?63 Hz? The switch choice?248?370VDCExchange input current2.8A/115 V 1.6A/ 230 Vefficiency78%76%Impulse currentCold start current?35ALeakage current?3.5mA/240VACProtection characteristicsOverload protection105%?135%Protection way: cut output reset: restartOvervoltage protection115%~135%Protection way: cut output reset: restartenvironmentWorking temperature, humidity-10??+60??20%?90 %RHKeep temperature, humidity-20??+85??10%?95 %RHVibrate resistance10?500Hz,2G 10min./1 cycle time, 60 minutes, the axissecurityCompression sexInput/output: 1.5 KVAC input and between to KVAC output and the earth: 1.5:?0.5KVACInsulation resistanceBetween the input and output, the input and output, and ground:?100M Ohms/500VDCStandardsSafety standardsAccord with?1950,TUV EN*EMC standardAccord with?EN* (CISPR22), EN*-3-2,-3,EN*-4-2,3,4,5,6,8,11; ENV*, EN*otherweight0.82Kgpackaging20pcs/18.5Kg/1.22CUFTnote1. All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ? conditions measuring income value.2. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement.3. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate.4. The power to consider as a device installed in final equipment, this equipment....
Please Note that this information was issued on BestB2B.com!
Insulation Panel,roof panels2024-01-29
EPS sandwich panel2024-01-29
Insulated Metal Panels Increas2024-01-29
Insulated Metal Roof Panel2024-01-29
Light Insulated Metal Wall Pa2024-01-29
Insulated Metal Wall Panels2024-01-29
Insulated sandwich panels / In2024-01-29
Trapezoidal Roof Panel / Wall2024-01-29
100G QSFP28 SWDM4 100m LC Opti2024-02-01
100G QSFP28 SR4 100M MPO Optic2024-02-01
200G QSFP56 SR4 100m MPO Optic2024-02-01
400G OSFP SR8 100m MPO Optical2024-02-01
400G QSFP-DD LR8 10KM LC Optic2024-02-01
400G QSFP-DD LR4 10KM LC Media2024-02-01
400G QSFP-DD 4x100G LR 10KM 2024-01-29