Move to www.1688club.com now,This Website will be closed
SearchSearch

D-120

ID:131750 View:477
Date Listed: 2016-10-22 18:06:59 Country: China»Zhejiang»yueqing
Poster: Xiaoyan yu Company: ZHEJIANG WEIHAO ELECTRONIC CO.,LTD
Location: No.231,WeiLiu Road Website: ZHEJIANG WEIHAO ELECTRONIC CO.,LTD
Email: wehodz@chnwh.com Mobile: 86-15325082200
Fax: 86-577-61777072 MSN:

Features:High efficiency, high reliabilitySwitch input voltage range choice100% full load and machine testProtection characteristics: short circuit/overload/pressureAir coolingWorking frequency 47~63 Hz1 year warrantySize: 199 * 110 * 50 mm (L * W * H)?modelD-120AD-120BCH1CH2CH1CH2outputDc output voltage5V12V5V24VOutput voltage tolerance?2%?6%?2%?7%Rated output current12A5A6A4AOutput current range0-12A0-5A0-6A0-4AOutput power120W126WRipple and the noise60mVp-p120mVp-p60mVp-p150mVp-pDc voltage adjustable scopeCH1?-5%,+10%CH1?-5%,+10%Start, rise, keep time200ms,50ms,20ms Loaded withinputInput voltage range88?132 VAC / 176?264VAC 47?63 Hz? The switch choice?248?370VDCExchange input current2.8A/115 V 1.6A/ 230 Vefficiency78%76%Impulse currentCold start current?35ALeakage current?3.5mA/240VACProtection characteristicsOverload protection105%?135%Protection way: cut output reset: restartOvervoltage protection115%~135%Protection way: cut output reset: restartenvironmentWorking temperature, humidity-10??+60??20%?90 %RHKeep temperature, humidity-20??+85??10%?95 %RHVibrate resistance10?500Hz,2G 10min./1 cycle time, 60 minutes, the axissecurityCompression sexInput/output: 1.5 KVAC input and between to KVAC output and the earth: 1.5:?0.5KVACInsulation resistanceBetween the input and output, the input and output, and ground:?100M Ohms/500VDCStandardsSafety standardsAccord with?1950,TUV EN*EMC standardAccord with?EN* (CISPR22), EN*-3-2,-3,EN*-4-2,3,4,5,6,8,11; ENV*, EN*otherweight0.82Kgpackaging20pcs/18.5Kg/1.22CUFTnote1. All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ? conditions measuring income value.2. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement.3. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate.4. The power to consider as a device installed in final equipment, this equipment....

Please Note that this information was issued on BestB2B.com!

Insulation Panel,roof panels2024-01-29

EPS sandwich panel2024-01-29

Insulated Metal Panels Increas2024-01-29

Insulated Metal Roof Panel2024-01-29

Light Insulated Metal Wall Pa2024-01-29

Insulated Metal Wall Panels2024-01-29

Insulated sandwich panels / In2024-01-29

Trapezoidal Roof Panel / Wall2024-01-29

100G QSFP28 SWDM4 100m LC Opti2024-02-01

100G QSFP28 SR4 100M MPO Optic2024-02-01

200G QSFP56 SR4 100m MPO Optic2024-02-01

400G OSFP SR8 100m MPO Optical2024-02-01

400G QSFP-DD LR8 10KM LC Optic2024-02-01

400G QSFP-DD LR4 10KM LC Media2024-02-01

400G QSFP-DD 4x100G LR 10KM 2024-01-29

Important Safety Warning: Avoid fraud by meeting all sellers in-person to pay for items. BestB2B.COM does not offer any transaction or payment services.