S-145
ID:131753 View:568次 |
Date Listed: | 2016-10-22 18:07:17 | Country: | China»Zhejiang»yueqing |
Poster: | Xiaoyan yu | Company: | ZHEJIANG WEIHAO ELECTRONIC CO.,LTD |
Location: | No.231,WeiLiu Road | Website: | ZHEJIANG WEIHAO ELECTRONIC CO.,LTD |
Email: | wehodz@chnwh.com | Mobile: | 86-15325082200 |
Fax: | 86-577-61777072 | MSN: |
Features:High efficiency, high reliability and low costSwitch input voltage range choice100% full load and machine testProtection characteristics: short circuit/overload/pressureAir coolingWorking frequency 25 KHz2 years warrantySize: 199*98*38mm (L*W*H)modelS-145-5S-145-7.5S-145-12S-145-15S-145-24S-145-48outputDc output voltage5V7.5V12V15V24V48VOutput voltage tolerance?2%?1%?1%?1%?1%?1%Rated output current25A18A12A9.6A6A3AOutput current range0-25A0-18A0-12A0-9.6A0-6A0-3AOutput power125W135W144W144W144W144WRipple and the noise100mVp-p120mVp-p120mVp-p120mVp-p150mVp-p240mVp-pDc voltage adjustable scope?10%-20%,+10%-12%,+10%-12%,+10%-12%,+16%-10%,+15%Start, rise, keep time100ms,50ms,20ms Loaded withinputInput voltage range88?132 VAC/176?264VAC by switch 47?63 Hz?Exchange input current3.2A/115 V 1.6A/ 230 Vefficiency78%80.5%80.5%81%83.5%82%Impulse currentCold start current?35A/230VACLeakage current?3.5 mA/240VACProtection characteristicsOverload protection115%?165%Protection way: cut output, restartOvervoltage protection115%~135%Protection way: cut output, restartenvironmentWorking temperature, humidity-10??+60??20%?90 %RHKeep temperature, humidity-20??+85??10%?95 %RHVibrate resistance10?500Hz,2G 10min./1 cycle time, 60 minutes, the axissecurityCompression sexInput/output: 1.5 KVAC input and between to KVAC output and the earth: 1.5:0.5 KVACInsulation resistanceBetween the input and output, the input and output, and ground:?100M Ohms/500VDCstandardSafety standardsAccord with?UL1012EMC standardAccord with?EN*,IEC801-2,3,4otherweight0.7Kgpackaging30pcs/21kg/1.22CUFTnote1.All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ? conditions measuring income value.2.Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement.3.Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate.4.Specific output curren....
Please Note that this information was issued on BestB2B.com!
Insulation Panel,roof panels2024-01-29
EPS sandwich panel2024-01-29
Insulated Metal Panels Increas2024-01-29
Insulated Metal Roof Panel2024-01-29
Light Insulated Metal Wall Pa2024-01-29
Insulated Metal Wall Panels2024-01-29
Insulated sandwich panels / In2024-01-29
Trapezoidal Roof Panel / Wall2024-01-29
100G QSFP28 SWDM4 100m LC Opti2024-02-01
100G QSFP28 SR4 100M MPO Optic2024-02-01
200G QSFP56 SR4 100m MPO Optic2024-02-01
400G OSFP SR8 100m MPO Optical2024-02-01
400G QSFP-DD LR8 10KM LC Optic2024-02-01
400G QSFP-DD LR4 10KM LC Media2024-02-01
400G QSFP-DD 4x100G LR 10KM 2024-01-29