Move to www.1688club.com now,This Website will be closed
SearchSearch

S-50

ID:140876 View:738
Date Listed: 2017-01-01 17:24:33 Country: China»Zhejiang»yueqing
Poster: Xiaoyan yu Company: ZHEJIANG WEIHAO ELECTRONIC CO.,LTD
Location: No.231,WeiLiu Road Website: ZHEJIANG WEIHAO ELECTRONIC CO.,LTD
Email: wehodz@chnwh.com Mobile: 86-15325082200
Fax: 86-577-61777072 MSN:

Features:?High efficiency, high reliability and low cost?Switch input voltage range choice?100% full load and machine test?Protection characteristics: short circuit/overloadAir cooling?Working frequency 37 KHz?Two years warranty?Size: 159*98*38mm(L*W*H)ModelS-50-5S-50-12S-50-15S-50-24S-50-48OUTPUTDC Voltage5V12V15V24V48VVoltage Tolerance?2%?1%?1%?1%?1%Rated Current10A4.2A3.4A2.1A1ACurrent Range0-10A0-4.2A0-3.4A0-2.1A0-1ARated Power50W50.4W51W50.4W48WRipple & Noise75mVp-p100mVp-p100mVp-p100mVp-p100mVp-pDC Adjustment Range+10,-5%?10%?10%?10%?10%Setup, Rise, Hold Time200ms,100ms,20ms Loaded withINPUTVoltage Range85?132 VAC/170?264VAC 47?63 Hz by switch 240?370VDCAC Curren1.3A/115 V 0.65A/ 230 VEfficiency71%78%78%82%84%Inrush CurrentCold start current?18A/115V 36A/230VLeakage Current?1 mA/240VACPROTECTIONOverload protection110%?160%Protection way: current limiting, automatic recoveryENVIRONMENTWorking temperature, humidity-10??+60??20%?90 %RHKeep temperature, humidity-20??+85??10%?95 %RHVibrate resistance10?500Hz,2G 10min./1 cycle time, 60 minutes, the axisSAFETYCompression sexInput/output: 1.5 KVAC input and between?1.5KVAC Output and to?0.5KVACInsulation resistanceBetween the input and output, the input and output, and ground:?100M Ohms/500VDCSTANDARDSafety standardsmeet UL1012EMC standardsDesign refer to FCC Part15 J Conduction Class BOTHERSweight0.5Kgpackaging30pcs/15.8Kg/0.99CUFTNOTE1.All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ? conditions measuring income value.2.Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement.3.Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate.4.Specific output current see output drop forehead curve.

Please Note that this information was issued on BestB2B.com!

Insulation Panel,roof panels2024-01-29

EPS sandwich panel2024-01-29

Insulated Metal Panels Increas2024-01-29

Insulated Metal Roof Panel2024-01-29

Light Insulated Metal Wall Pa2024-01-29

Insulated Metal Wall Panels2024-01-29

Insulated sandwich panels / In2024-01-29

Trapezoidal Roof Panel / Wall2024-01-29

100G QSFP28 SWDM4 100m LC Opti2024-02-01

100G QSFP28 SR4 100M MPO Optic2024-02-01

200G QSFP56 SR4 100m MPO Optic2024-02-01

400G OSFP SR8 100m MPO Optical2024-02-01

400G QSFP-DD LR8 10KM LC Optic2024-02-01

400G QSFP-DD LR4 10KM LC Media2024-02-01

400G QSFP-DD 4x100G LR 10KM 2024-01-29

Important Safety Warning: Avoid fraud by meeting all sellers in-person to pay for items. BestB2B.COM does not offer any transaction or payment services.