NES-50
ID:140886 View:635次 |
Date Listed: | 2017-01-01 17:25:48 | Country: | China»Zhejiang»yueqing |
Poster: | Xiaoyan yu | Company: | ZHEJIANG WEIHAO ELECTRONIC CO.,LTD |
Location: | No.231,WeiLiu Road | Website: | ZHEJIANG WEIHAO ELECTRONIC CO.,LTD |
Email: | wehodz@chnwh.com | Mobile: | 86-15325082200 |
Fax: | 86-577-61777072 | MSN: |
NES-50W series Efficient single switching power supplyFeatures??universal AC input??Small volume,low weight,high efficiency?Protections?short circuit/over load/over voltage?cooling by free air convection?LED indicator for power on?100% full load burn-in test?2 Year warrantyModelNES-50-5NES-50-12NES-50-15NES-50-24outputDC voltage5V12V15V24VVoltage tolerance?2%?1%?1%?1%Rated current10A4.2A3.4A2.2ACurrent range0~10A0~4.2A0~3.4A0~2.2ARated power50W50.4W51W50.4WRipple&noise80mvp-p100mvp-p120mvp-p120mvp-pDCvoltage ADJ.range-9%~+10%?10%?10%?10%inputVoltage range85~264VAC,120~370VDCfrequency47~63HZAC current1.2A/115VAC,0.6A/230VACefficiency79%82%82%84%Inrush currentCold start current 18A/115VAC,36A/230VACLeakage current< 2mA/240VACprotectionOver loadRated output power110%~150% start over load protectionprotection type?hiccup mode,auto-recovery after fault condition is removedover voltage6.8~8.2V15.6~17.8V18.6~20.8V30.6~33.2Vprotection type?hiccup mode,auto-recovery after fault condition is removedenvironmentWorking temp,humidity-20?~+60?,20%~90%RHStoragetemp,humidity-40?~+85?,10%~95%RH non-condensingWithstand vibration10~500HZ,2G 10min/1cycle,period for 60 minutes,each axessafetyWithstand voltageI/P-O/P?3KVAC I/P-FG?1.5KVAC O/P-FG?0.5KVACIsolated resistanceI/P-O/P,I/P-FG,O/P-FG?100M ohms/500VDCFitstandardSafety standardFit UL1012EMC standardconform EN*,CLASSAothersDimension129*98*38mm (L*W*H)Weight/packing0.41kg/45pcs/18.5kg/0.027m?/0.96CUFTnote1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25?of ambient temperature.2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.3. Tolerance : includes set up tolerance, line regulation and load regulation.
Please Note that this information was issued on BestB2B.com!
Insulation Panel,roof panels2024-01-29
EPS sandwich panel2024-01-29
Insulated Metal Panels Increas2024-01-29
Insulated Metal Roof Panel2024-01-29
Light Insulated Metal Wall Pa2024-01-29
Insulated Metal Wall Panels2024-01-29
Insulated sandwich panels / In2024-01-29
Trapezoidal Roof Panel / Wall2024-01-29
100G QSFP28 SWDM4 100m LC Opti2024-02-01
100G QSFP28 SR4 100M MPO Optic2024-02-01
200G QSFP56 SR4 100m MPO Optic2024-02-01
400G OSFP SR8 100m MPO Optical2024-02-01
400G QSFP-DD LR8 10KM LC Optic2024-02-01
400G QSFP-DD LR4 10KM LC Media2024-02-01
400G QSFP-DD 4x100G LR 10KM 2024-01-29