Move to www.1688club.com now,This Website will be closed
SearchSearch

Bottom Loading Oil Controller

ID:179895 View:1305
Date Listed: 2019-03-08 11:34:15 Country: China»Jiangsu»lianyungang
Poster: Harry Company: Lianyungang Hechang Machinery Co.,Ltd
Location: No. 1, zhao zhuang road, haizhou economic development zone Website: Lianyungang Hechang Machinery Co.,Ltd
Email: lyg_loadingarm@lyghechang.com Mobile: +8651885381889
Fax: MSN:

Bottom Loading Oil Controller, Overfill Detection For Oil, Bottom Loading Grounding Controller 1    System introduction ET - SLC-B overfill detection-bottom  loading and grounding controller is designed for  bottom loading oil system , can effectively prevent liquid overflow and ensure the  grounding resistance conforms to the safety standards of instrumentation, system for oil storage and transportation of chemical products. Ex-mark is Exd[ia]IIBT4. 2  Working principle and System composition 2.1 Working principle ET - SLC-B overfill detection-bottom  loading and grounding controller  is designed for the bottom  loading oil  system .  when the liquid level exceeds alarm position or ground loop in excess of the prescribed value, the system output sound and light alarm signal for field personnel understand the system working status in time, at the same time the output relay switch control signal. 3 the product characteristics 1. The system USES digital circuit design, stable performance, strong anti-interference ability; 2. To connect 8 overfill sensor of  meeting API Rp1004  and 1 grounding bolt; 3. Compatible with foreign Scully, Civacon, Liquip, Dixon brands such as overfill sensor; 4. Plug meet  API rp1004 standard design, compatible with socket of meet API  Rp1004 5.Ensure grouding resistance < 55 Ω 6.Provide sound and light alarm signal, in a timely manner to understand system working state 7.Switch signal output interface capacity 10A, 30 VDC or 10 A, 250 VAC. 4   System parameters 1. Working voltage: 220 VAC ± 10% 2. The working current: < 20 mA 3. The working temperature: - 40 ℃ ~ 60 ℃ 4. Response time: < 0.5 s 5. Grounding resistance: < 55 Ω 6. Protection grade: Ip65 7. Ex-mark : Exd[ia] IIBT4 8. Warning: sound and light alarm 9. The input signal: in accordance with API RP1004, EN* standards 10. The output signal: relay output, normally open norm....

Please Note that this information was issued on BestB2B.com!

Insulation Panel,roof panels2024-01-29

EPS sandwich panel2024-01-29

Insulated Metal Panels Increas2024-01-29

Insulated Metal Roof Panel2024-01-29

Light Insulated Metal Wall Pa2024-01-29

Insulated Metal Wall Panels2024-01-29

Insulated sandwich panels / In2024-01-29

Trapezoidal Roof Panel / Wall2024-01-29

100G QSFP28 SWDM4 100m LC Opti2024-02-01

100G QSFP28 SR4 100M MPO Optic2024-02-01

200G QSFP56 SR4 100m MPO Optic2024-02-01

400G OSFP SR8 100m MPO Optical2024-02-01

400G QSFP-DD LR8 10KM LC Optic2024-02-01

400G QSFP-DD LR4 10KM LC Media2024-02-01

400G QSFP-DD 4x100G LR 10KM 2024-01-29

Important Safety Warning: Avoid fraud by meeting all sellers in-person to pay for items. BestB2B.COM does not offer any transaction or payment services.